Prevent failures in olefin-cracking operations
09.01.2011
| Gupta, R. P., Reliance Industries Limited, Nagothane Manufacturing Division, Raigad, India; Pathak, H., Reliance Industries Ltd., Nagothane, India
Failure analysis identifies root causes for damages to selective exchangers
Keywords:
[olefins]
[metal dusting]
[furnaces]
[ultra-selective exchange]
[transfer lines]
[pipe failure]
[heat exchanger]
At the Nagothane olefins facility, the inner thermal sleeve, constructed with Incolloy 800H, for double-pipe ultra-selective exchangers (USXs) of an ethylene cracking furnace showed grooves/pitting/fissures damage after 14 years of service. Metallurgical examination and testing of the damaged samples revealed that the damage to the USX Alloy 800H thermal sleeve occurred due to metal dusting, a phenomenon caused by elevated temperatures and failures in the purge-steam supply. In this case history, the authors discuss how the damaged USXs were replaced and the selection process for a better design without a thermal sleeve was investigated.
Already have an account?
Subscribe
Subscribe today and gain unlimited and immediate access to the site. Plus, you'll receive the next 12 issues of the magazine in your choice of print or digital format. Start your subscription today.
Subscribe
|
Free trial
Start a free trial and gain immediate access to the current issue of the magazine plus additional, select content.
30 Day Trial
|