Hydrocarbon Processing Copying and distributing are prohibited without permission of the publisher
Email a friend
  • Please enter a maximum of 5 recipients. Use ; to separate more than one email address.



Loose pipe fittings blamed for sulfuric acid spill at Tesoro refinery in California

08.20.2014  |  HP News

The technical report from the CSB concluded that a February 2014 spill at Tesoro's Martinez refinery resulted from insufficient tightening between a tube and a compression joint.

Keywords:

The US Chemical Safety Board (CSB) released a technical evaluation report on tubing samples taken from the Tesoro refinery in Martinez, California, concluding that a sulfuric acid spill on February 12, 2014, resulted from insufficient tightening between a tube and a compression joint at a sulfuric acid sampling station.

The spill burned two workers in the refinery’s alkylation unit, who were transported to the nearest hospital burn unit by helicopter.

The spill continued for 2.5 hours, by which time an estimated 84,000 pounds of sulfuric acid was released from equipment onto the refinery grounds and into a process sewer system. Cal/OSHA ordered the process unit to remain shutdown from February 18 until February 28 based on worker testimony that the unit was unsafe.

The Cal/OSHA PSM Unit is also conducting a comprehensive inspection at the Tesoro Refinery with an emphasis on mechanical integrity and operating procedures.

The California Division of Occupational Safety and Health, or Cal/OSHA, participated in this technical evaluation as part of its regulatory investigation.

The incident occurred when the operators opened a block valve to return an acid sampling system back to service. Very shortly after this block valve had been fully opened, the tubing directly downstream of the valve came apart, spraying two operators with acid.

The report, prepared by Anamet -- a California-based materials engineering and laboratory testing firm-- details findings from laboratory examination of the stainless steel tube assembly recovered by Cal/OSHA following the incident. The report concludes that the sulfuric acid spill immediately followed the failure of a 0.75-inch diameter stainless steel tubing connector that came apart due to insufficient tightening of the tube during installation. 

The tube was being pressurized at the time of the incident, and was part of a sulfuric acid sampling station in the refinery’s alkylation unit. The insufficient tightening between the tube and a compression joint allowed the tube to be forced from the joint, most likely by internal pressure. 

Chemical analysis conducted on the tube assembly found that all of its components, including the tube itself, are constructed of Type 316 stainless steel. Type 316 stainless steel is common in industrial processes that require a high level of resistance to corrosion. 

On March 10, 2014, in the same sulfuric acid alkylation unit, two contract workers were sprayed with sulfuric acid while conducting planned maintenance work to remove piping in the alkylation unit. The sulfuric acid sprayed the two workers when they cut into the piping using a portable band saw.

The piping was not drained of process chemicals and was still under pressure, despite the refinery’s issuance of a “hot work” permit for the activity, according to the CSB. Although the contractors were wearing protective suits while performing the work, they were still burned by the acid. 

One worker was exposed when his acid suit got caught on scaffolding as he evacuated from the immediate area. The second worker was burned when acid that remained on his acid suit drained onto his neck during decontamination in the safety shower.

Both workers were taken to a local hospital by ambulance for evaluation and treatment for their chemical burn injuries.

“This incident highlights the need for strong process safety management at facilities that ensures mechanical integrity is verified prior to the introduction of hazardous chemicals into equipment," said CSB chairperson Rafael Moure-Eraso. "However, on March 10, there was another incident that also burned two workers with acid in the same production unit. Four workers burned by sulfuric acid in less than a month clearly demonstrates there are significant opportunities within the refinery for improvement in safety performance.”

In the course of its investigation, the CSB said it identified multiple incidents at the Martinez refinery over the past several years involving the uncontrolled release of sulfuric acid. These include chemical burns to a contract worker in June 2010, an August 2012 incident where two Tesoro workers were sprayed with acid when a temporary hose ruptured and a January 2012 acid release from a failed pump which injured another worker.

The CSB is an independent federal agency charged with investigating serious chemical accidents.  The agency's board members are appointed by the President and confirmed by the Senate. CSB investigations look into all aspects of chemical accidents, including physical causes such as equipment failure as well as inadequacies in regulations, industry standards, and safety management systems.

The board does not issue citations or fines but does make safety recommendations to plants, industry organizations, labor groups, and regulatory agencies such as OSHA and EPA



Have your say
  • All comments are subject to editorial review.
    All fields are compulsory.

ASHVIN MEHTA
08.29.2014

In my opinion, the foremost issue is the type of the SS tube fitting, single ferrule versus double ferrule. The second issue here is installation of this SS tube fitting. Instrument technician should have followed the guidelines on installation details like, amount of torque and nos. of turns required to tighten the ferrule over tube, placing the ferrules correctly over the tube and lastly performing the leak/pressure test of the installation.

Marcos Menezes
08.26.2014

The Stainless steel AISI 316 is poor in high corrosion is a problem the production ,is better AISI317L Corrosion Resistance high.same UHB Stainless34L or German W. Nr.1.4449 or AISI316+Nb , AISI316+Ti or ELC Stainless Steel UHB Stainless3Lor 3LN

stella Dominguez
08.23.2014

No mentioning if the researchers look into the training program of the workers. Work instructions, mechanical integrity programs or any procedures are worthless if the end users are not trained. As well as the quantity of personnel available. Profit margins need to be met most of the time sacrificing the implementation of well written procedures.

John
08.21.2014

What was the Tube Fitting Brand involved in the incidence please?
Many a times instrumentation technicians forget to check if there are Ferrules or Olives in the fitting !

Related articles

FEATURED EVENT


Sign-up for the Free Daily HP Enewsletter!

Boxscore Database

A searchable database of project activity in the global hydrocarbon processing industry

Poll

Should the US allow exports of crude oil? (At present, US companies can export refined products derived from crude but not the raw crude itself.)


65%

35%




View previous results

Popular Searches

Please read our Term and Conditions and Privacy Policy before using the site. All material subject to strictly enforced copyright laws.
© 2014 Hydrocarbon Processing. © 2014 Gulf Publishing Company.